HD 163
RG 11 Trishield
Class A+
Application Area
This RG11 cable is specifically designed for use in multimedia networks and complies with screening of class A+ level, which is the high demand of Cable Network Operators. It has characteristics such as low loss, high screening efficiency, and high resistance to aging. It is available in PVC, PE or HFFR Jacketed versions.
Cable Construction
Inner Conductor
Ø 1.63 mm Bare Copper
Insulation 
Ø 7.20 mm Gas Injected
Skin/Foam/Skin PE
1st Shielding
Aluminum Foil
Bonded to the insulation
2nd Shielding 
Tinned Copper Wire Braiding
3rd Shielding
Aluminum Foil
Bonded to the Jacket
Outer Sheath
Ø 10.0 mm PVC, HFFR* or PE
Technical Properties
Copper Weight 34 kg/km
Min. Bending Radius 75mm
Max. Tensile Strength 225 N
Operating Temperature -30 °C ... + 70 °C
Packing 100 / 300 / 500 /1000m
Electrical Properties
Impedance 75+2 Ω
Capacitance 53 + 2 pF/m
Velocity of Propagation 84 %
Insulation Resistance > 2 GΩxkm
Operating Voltage 2000 V
Test Voltage 5000 V
Inner Conductor DCR < 8.50 Ω/km
Attenuations (20°C)
5 MHz 1.20 dB/100m
50 MHz 2.80 dB/100m
230 MHz 6.10 dB/100m
470 MHz 8.90 dB/100m
860 MHz 12.60 dB/100m
1000 MHz 13.90 dB/100m
1200 MHz 15.10 dB/100m
2150 MHz 20.70 dB/100m
3000 MHz 25.20 dB/100m
Return Loss (20°C)
5-470 MHz > 30 dB
470-1200 MHz > 25 dB
1200-2000 MHz > 20 dB
2000-3000 MHz > 18 dB
Transfer Impedance
5-30 MHz ≤ 1.5 mΩ/m
Screen Attenuation
30-1200 MHz ≥ 110 dB
1200-2000 MHz ≥   95 dB
2000-3000 MHz ≥   85 dB
Standards
Screening Class Class A+
EN 50117-2-4  
EN 50117-2-5  
 
Product
Name
Outer Sheath
Material
Euro
Class
Cable
Weight
Flame
Retardancy
Corrosive Gases
Test
Smoke
Density
Download
Data Sheet
ÖREN HD 163  PVC Eca 97 kg/km EN 60332-1-2 N/A N/A PVC  
ÖREN HD 163 HFFR HFFR Dca 100 kg/km EN 60332-1-2 EN 50267-2-3 EN 61034-2 HFFR
ÖREN HD 163 PE PE Fca 85 kg/km N/A N/A N/A PE